;******************************************************************************* ;** ** ;** INTEL CONFIDENTIAL ** ;** ** ;** Copyright 2007-2010 Intel Corporation All Rights Reserved. ** ;** ** ;** The material contained or described herein and all documents related ** ;** to such material ("Material") are owned by Intel Corporation or its ** ;** suppliers or licensors. Title to the Material remains with Intel ** ;** Corporation or its suppliers and licensors. The Material contains trade ** ;** secrets and proprietary and confidential information of Intel or its ** ;** suppliers and licensors. The Material is protected by worldwide ** ;** copyright and trade secret laws and treaty provisions. No part of the ** ;** Material may be used, copied, reproduced, modified, published, ** ;** uploaded, posted, transmitted, distributed, or disclosed in any way ** ;** without Intel's prior express written permission. ** ;** ** ;** No license under any patent, copyright, trade secret or other ** ;** intellectual property right is granted to or conferred upon you by ** ;** disclosure or delivery of the Materials, either expressly, by ** ;** implication, inducement, estoppel or otherwise. Any license under such ** ;** intellectual property rights must be express and approved by Intel in ** ;** writing. ** ;** ** ;******************************************************************************* ; ;******************************************************************************* ; INF for Intel(R) 10 Gigabit PCIe Network Adapters ;******************************************************************************* ; [Version] Signature = "$Windows NT$" Class = Net ClassGUID = {4d36e972-e325-11ce-bfc1-08002be10318} Provider = %Intel% CatalogFile = ixn51x64.cat DriverVer = 01/14/2011,2.7.28.0 [Manufacturer] %Intel% = Intel, NTamd64.5.2, NTamd64.5.2.1, NTamd64.6.0 [Intel] [Intel.NTamd64.5.2] ; DisplayName Section DeviceID ; ----------- ------- -------- %O10A6.DeviceDesc% = NO_DRV, PCI\VEN_8086&DEV_10A6 %N10F7.KX4.Dual.Description% = N10F7, PCI\VEN_8086&DEV_10F7&SUBSYS_000D8086 %N10F7.KX4.FEM.Description% = N10FC, PCI\VEN_8086&DEV_10F7&SUBSYS_7B12108E %N10F7.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10F7 %N1514.KX4.Dual.Description% = N1514, PCI\VEN_8086&DEV_1514&SUBSYS_000B8086 %N10F8.KX4.KR.Dual.Description% = N10F8_NoSec, PCI\VEN_8086&DEV_10F8&SUBSYS_000C8086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_7B11108E %N1507.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_1507&SUBSYS_7B10108E %N1517.KR.Dual.Description% = N10FC, PCI\VEN_8086&DEV_1517&SUBSYS_006A1137 %N10F8.Generic.Description% = N10F8, PCI\VEN_8086&DEV_10F8 %N152A.Generic.Description% = N10F8, PCI\VEN_8086&DEV_152A %N10F9.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10F9 %N10FB.Generic.Description% = N10FB_PM, PCI\VEN_8086&DEV_10FB&SUBSYS_11A91734 %N10FB.SFI.Dual.Description% = N10FB_NoSec, PCI\VEN_8086&DEV_10FB&SUBSYS_7A118086 %N10FB.CopperDA.Dual.Description% = N10FC, PCI\VEN_8086&DEV_10FB&SUBSYS_00028086 %N10FB.SFI.Single.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_000A8086 %N10FB.SFI.Single.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_00068086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_00038086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_000C8086 %N10FB.Generic.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_152D8975 %N10FB.Generic.Description% = N10FB, PCI\VEN_8086&DEV_10FB %N10FC.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10FC %N1529.Generic.Description% = N10FB, PCI\VEN_8086&DEV_1529 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A02C8086 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A21C8086 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A03C8086 %N151C.Copper.Dual.Sun.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_7B13108E %N151C.Generic.Description% = N151C, PCI\VEN_8086&DEV_151C [Intel.NTamd64.5.2.1] [Intel.NTamd64.6.0] [NO_DRV] Characteristics = 0x01 Include = machine.inf Needs = NO_DRV [NO_DRV.Services] Include = machine.inf Needs = NO_DRV.Services ; ------------------------------------------------------ ; Intel(R) 10 Gigabit X520 Server Adapters ; ------------------------------------------------------ [N10FB] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB.Services] AddService = %ServiceName%, 2, Service, EventLog [N10FB.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10FB.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 10 Gigabit X520 Server Adapters ; ------------------------------------------------------ [N10FB_NoSec] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_NoSec.Services] AddService = %ServiceName%, 2, Service, EventLog [N10FB_NoSec.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10FB_NoSec.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 Dual 10 Gigabit Network Connection ; ------------------------------------------------------ [N10FB_PM] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg, Powermgmt.reg, PMEEnabled.reg, WakeOnSlot.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_PM.Services] AddService = %ServiceName%, 2, Service, EventLog [N10FB_PM.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10FB_PM.CoInstallers] AddReg = CoInstaller_AddReg, CoInKPM.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 10 Gigabit Dual Port Network Connection ; ------------------------------------------------------ [N10FC] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FC.Services] AddService = %ServiceName%, 2, Service, EventLog [N10FC.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10FC.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ----------------------------------------------- ; Intel(R) Ethernet Server Adapter X520-T1/T2 ; ----------------------------------------------- [N151C] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Dualspeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N151C.Services] AddService = %ServiceName%, 2, Service, EventLog [N151C.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N151C.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet Mezzanine Adapter X520-KX4 ; ------------------------------------------------------ [N10F7] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Powermgmt.reg, PMEEnabled.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F7.Services] AddService = %ServiceName%, 2, Service, EventLog [N10F7.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10F7.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz ; ------------------------------------------------------ [N1514] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N1514.Services] AddService = %ServiceName%, 2, Service, EventLog [N1514.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N1514.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz ; ------------------------------------------------------ [N10F8_NoSec] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = SmartSpeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F8_NoSec.Services] AddService = %ServiceName%, 2, Service, EventLog [N10F8_NoSec.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10F8_NoSec.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 10 Gigabit Dual Port Backplane Connection ; ------------------------------------------------------ [N10F8] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI AddReg = Default.reg, RSS.reg, LLI.reg, Uninstall.reg AddReg = Powermgmt.reg, SmartSpeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F8.Services] AddService = %ServiceName%, 2, Service, EventLog [N10F8.HW] Include = machine.inf Needs = PciIoSpaceNotRequired [N10F8.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ;------------------------------------------------------------------------------- ; Registry Settings ;------------------------------------------------------------------------------- [Default.reg] HKR, Ndi\Interfaces, UpperRange, 0, "ndis5" HKR, Ndi\Interfaces, LowerRange, 0, "ethernet" HKR, Ndi, Service, 0, %ServiceName% ; *FlowControl HKR, Ndi\Params\*FlowControl, ParamDesc, 0, %FlowControl% HKR, Ndi\Params\*FlowControl, default, 0, "3" HKR, Ndi\Params\*FlowControl\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*FlowControl\Enum, "1", 0, %FlowControl_TxOnly% HKR, Ndi\Params\*FlowControl\Enum, "2", 0, %FlowControl_RxOnly% HKR, Ndi\Params\*FlowControl\Enum, "3", 0, %FlowControl_Full% HKR, Ndi\Params\*FlowControl, type, 0, "enum" ; *TransmitBuffers HKR, Ndi\params\*TransmitBuffers, ParamDesc, 0, %TransmitBuffers% HKR, Ndi\params\*TransmitBuffers, default, 0, "512" HKR, Ndi\params\*TransmitBuffers, min, 0, "128" HKR, Ndi\params\*TransmitBuffers, max, 0, "16384" HKR, Ndi\params\*TransmitBuffers, step, 0, "64" HKR, Ndi\params\*TransmitBuffers, Base, 0, "10" HKR, Ndi\params\*TransmitBuffers, type, 0, "int" ; *ReceiveBuffers HKR, Ndi\params\*ReceiveBuffers, ParamDesc, 0, %ReceiveBuffers% HKR, Ndi\params\*ReceiveBuffers, default, 0, "512" HKR, Ndi\params\*ReceiveBuffers, min, 0, "128" HKR, Ndi\params\*ReceiveBuffers, max, 0, "2048" HKR, Ndi\params\*ReceiveBuffers, step, 0, "64" HKR, Ndi\params\*ReceiveBuffers, Base, 0, "10" HKR, Ndi\params\*ReceiveBuffers, type, 0, "int" ; *TCPChecksumOffloadIPv4 HKR, Ndi\Params\*TCPChecksumOffloadIPv4, ParamDesc, 0, %TCPChksumOffv4% HKR, Ndi\Params\*TCPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4, type, 0, "enum" ; *UDPChecksumOffloadIPv4 HKR, Ndi\Params\*UDPChecksumOffloadIPv4, ParamDesc, 0, %UDPChksumOffv4% HKR, Ndi\Params\*UDPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4, type, 0, "enum" ; *IPChecksumOffloadIPv4 HKR, Ndi\Params\*IPChecksumOffloadIPv4, ParamDesc, 0, %IPChksumOffv4% HKR, Ndi\Params\*IPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*IPChecksumOffloadIPv4, type, 0, "enum" ; Network Address HKR, Ndi\params\NetworkAddress, ParamDesc, 0, %LAA% HKR, Ndi\params\NetworkAddress, Default, 0, "" HKR, Ndi\params\NetworkAddress, type, 0, "edit" HKR, NDI\params\NetworkAddress, LimitText, 0, "12" HKR, NDI\params\NetworkAddress, UpperCase, 0, "1" HKR, NDI\params\NetworkAddress, optional, 0, "1" ;Log Link State Event HKR,Ndi\Params\LogLinkStateEvent, ParamDesc, 0, %LogLinkState% HKR,Ndi\Params\LogLinkStateEvent, Type, 0, "enum" HKR,Ndi\Params\LogLinkStateEvent, Default, 0, "51" HKR,Ndi\Params\LogLinkStateEvent\Enum, "51", 0, %Enabled% HKR,Ndi\Params\LogLinkStateEvent\Enum, "16", 0, %Disabled% HKR,, LogLinkStateEvent, 0, "51" ; Interrupt Throttle Rate HKR, Ndi\Params\ITR, ParamDesc, 0, %InterruptThrottleRate% HKR, Ndi\Params\ITR, default, 0, "65535" HKR, Ndi\Params\ITR\Enum, "65535", 0, %Adaptive% HKR, Ndi\Params\ITR\Enum, "2000", 0, %Extreme% HKR, Ndi\Params\ITR\Enum, "950", 0, %High% HKR, Ndi\Params\ITR\Enum, "488", 0, %Medium% HKR, Ndi\Params\ITR\Enum, "200", 0, %Low% HKR, Ndi\Params\ITR\Enum, "0", 0, %Off% HKR, Ndi\Params\ITR, type, 0, "enum" ; *PriorityVLANTag HKR, Ndi\Params\*PriorityVLANTag, ParamDesc, 0, %PriorityVLANTag% HKR, Ndi\Params\*PriorityVLANTag, default, 0, "3" HKR, Ndi\Params\*PriorityVLANTag\Enum, "0", 0, %PriorityVlanDisabled% HKR, Ndi\Params\*PriorityVLANTag\Enum, "1", 0, %PriorityEnabled% HKR, Ndi\Params\*PriorityVLANTag\Enum, "2", 0, %VlanEnabled% HKR, Ndi\Params\*PriorityVLANTag\Enum, "3", 0, %PriorityVlanEnabled% HKR, Ndi\Params\*PriorityVLANTag, type, 0, "enum" ; *LsoV1IPv4 HKR, Ndi\Params\*LsoV1IPv4, ParamDesc, 0, %LsoV1IPv4% HKR, Ndi\Params\*LsoV1IPv4, default, 0, "1" HKR, Ndi\Params\*LsoV1IPv4\Enum, "0", 0, %Off% HKR, Ndi\Params\*LsoV1IPv4\Enum, "1", 0, %On% HKR, Ndi\Params\*LsoV1IPv4, type, 0, "enum" ; EnableDca HKR, PROSetNdi\Params\EnableDca, ParamDesc, 0, %EnableDca% HKR, PROSetNdi\Params\EnableDca, default, 0, "1" HKR, PROSetNdi\Params\EnableDca, type, 0, "enum" HKR, PROSetNdi\Params\EnableDca\Enum, "1", 0, %Enabled% HKR, PROSetNdi\Params\EnableDca\Enum, "0", 0, %Disabled% HKR,, EnableDca, 2, "1" ; *JumboPacket HKR, Ndi\Params\*JumboPacket, ParamDesc, 0, %JumboPacket% HKR, Ndi\Params\*JumboPacket, default, 0, "1514" HKR, Ndi\Params\*JumboPacket\Enum, "1514", 0, %Disabled% HKR, Ndi\Params\*JumboPacket\Enum, "4088", 0, %Bytes4088% HKR, Ndi\Params\*JumboPacket\Enum, "9014", 0, %Bytes9014% HKR, Ndi\Params\*JumboPacket, type, 0, "enum" ; Miscellanous defaults HKR,, MulticastFilterType, 0, "0" HKR,, VlanFiltering, 0, "0" [Dualspeed.reg] HKR, Ndi\params\*SpeedDuplex, ParamDesc, 0, %SpeedDuplex% HKR, Ndi\params\*SpeedDuplex, default, 0, "0" HKR, Ndi\params\*SpeedDuplex, type, 0, "enum" HKR, Ndi\params\*SpeedDuplex\enum, "0", 0, %AutoNegotiation% HKR, Ndi\params\*SpeedDuplex\enum, "6", 0, %1000Mb_Full_Duplex% [Force10G.reg] HKR, Ndi\params\*SpeedDuplex\enum, "7", 0, %10Gb_Full_Duplex% [RSS.reg] ; NumRssQueues HKR, Ndi\Params\NumRssQueues, ParamDesc, 0, %NumRssQueues% HKR, Ndi\Params\NumRssQueues, default, 0, "2" HKR, Ndi\Params\NumRssQueues, type, 0, "enum" HKR, Ndi\Params\NumRssQueues\Enum, "1", 0, %1queue% HKR, Ndi\Params\NumRssQueues\Enum, "2", 0, %2queues% HKR, Ndi\Params\NumRssQueues\Enum, "4", 0, %4queues% ; *RSS HKR, Ndi\Params\*RSS, ParamDesc, 0, %RSS% HKR, Ndi\Params\*RSS, default, 0, "1" HKR, Ndi\Params\*RSS, type, 0, "enum" HKR, Ndi\Params\*RSS\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*RSS\Enum, "1", 0, %Enabled% [LLI.reg] HKR, PROSetNdi\Params\EnableLLI, ParamDesc, 0, %EnableLLI% HKR, PROSetNdi\Params\EnableLLI, default, 0, "0" HKR, PROSetNdi\Params\EnableLLI, type, 0, "enum" HKR, PROSetNdi\Params\EnableLLI\Enum, "0", 0, %Disabled% HKR, PROSetNdi\Params\EnableLLI\Enum, "1", 0, %LLIPortBased% HKR, PROSetNdi\Params\EnableLLI\Enum, "2", 0, %LLIPSHBased% HKR,, EnableLLI, 2, "0" HKR, PROSetNdi\Params\LLIPorts, ParamDesc, 0, %LLIPorts% HKR, PROSetNdi\Params\LLIPorts, default, 0, "" HKR, PROSetNdi\Params\LLIPorts, type, 0, "edit" HKR, PROSetNdi\Params\LLIPorts, UpperCase, 0, "1" HKR, PROSetNdi\Params\LLIPorts, optional, 0, "1" HKR, PROSetNdi\Params\LLIPorts, multi_string, 0, "1" HKR,, LLIPorts, 0x00010002, "" [Powermgmt.reg] ; EnablePME HKR,Ndi\Params\EnablePME, ParamDesc, 0, %Enable_PME% HKR,Ndi\Params\EnablePME, Type, 0, "enum" HKR,Ndi\Params\EnablePME, Default, 0, "0" HKR,Ndi\Params\EnablePME\Enum, "1", 0, %Enabled% HKR,Ndi\Params\EnablePME\Enum, "0", 0, %Disabled% [PMEEnabled.reg] HKR,, EnablePME, 0, "1" [WakeOnSlot.reg] HKR,, WakeOnSlot, 0, 0 [SmartSpeed.reg] HKR,Ndi\Params\SmartSpeed, ParamDesc, 0, %SmartSpeed% HKR,Ndi\Params\SmartSpeed, Type, 0, "enum" HKR,Ndi\Params\SmartSpeed, Default, 0, "0" HKR,Ndi\Params\SmartSpeed\Enum, "0", 0, %Enabled% HKR,Ndi\Params\SmartSpeed\Enum, "2", 0, %Disabled% [AddEventLog] HKR,, EventMessageFile, 0x00020000, %EventLogMessageDllPath% HKR,, TypesSupported, 0x00010001, 7 ;----------------------------------------------------------------------------- ; Uninstall parameters ;----------------------------------------------------------------------------- [Uninstall.reg] HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10A6, 0, "10A6" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F9, 0, "10F9" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 151C, 0, "151C" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10FB, 0, "10FB" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10FC, 0, "10FC" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1529, 0, "1529" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F8, 0, "10F8" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 152A, 0, "152A" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F7, 0, "10F7" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1507, 0, "1507" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1514, 0, "1514" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1517, 0, "1517" HKLM,Software\Intel\Prounstl\Dins, ixn51x64.din, 0, "8259x.Uninstall" HKLM,Software\Intel\Prounstl\Services, %ServiceName%, 0, ixn51x64.sys ;----------------------------------------------------------------------------- ; Driver "service" installation settings ;----------------------------------------------------------------------------- [Service] DisplayName = %Service.Displayname% ServiceType = 1 ;%SERVICE_KERNEL_DRIVER% StartType = 3 ;%SERVICE_DEMAND_START% ErrorControl = 1 ;%SERVICE_ERROR_NORMAL% ServiceBinary = %12%\ixn51x64.sys LoadOrderGroup = NDIS ;----------------------------------------------------------------------------- ; Event Log settings ;----------------------------------------------------------------------------- [EventLog] AddReg = AddEventLog ;----------------------------------------------------------------------------- ; Coinstaller installation ;----------------------------------------------------------------------------- [CoInstallerCopyFiles] NicCo2.dll,,,0x00000010 ;don't overwrite NicInIXN.dll [CoInstaller_AddReg] HKR,, CoInstallers32, 0x00010000, "NicCo2.dll,NicCoInstallerEntry" HKR,, NicCoPlugins, 0x00010000, "NicInIXN.dll,NicCoInstallerEntry" [CoInK.reg] HKR,, CoInstallFlag, 0x00010001, 0x00201000 [CoInKPM.reg] HKR,, CoInstallFlag, 0x00010001, 0x00201400 [CopyFiles] ixn51x64.sys,,,2 [MessageDll.CopyFiles] ixnmsg.dll,,,2 [Uninstall.CopyFiles] ixn51x64.din,,,2 ;----------------------------------------------------------------------------- ; DestinationDirs ;----------------------------------------------------------------------------- [DestinationDirs] CopyFiles = 12 DefaultDestDir = 11 Uninstall.CopyFiles = 11 CoInstallerCopyFiles = 11 MessageDll.CopyFiles = 11 [SourceDisksNames] 1 = %DiskName%,,, ;----------------------------------------------------------------------------- ; SourceDisksFiles ;----------------------------------------------------------------------------- [SourceDisksFiles] ixn51x64.sys = 1 ixn51x64.din = 1 ixnmsg.dll = 1 NicCo2.dll = 1 NicInIXN.dll = 1 [Strings] EnableLLI = "Low Latency Interrupts" LLIPorts = "Low Latency Interrupt Ports" LLIPortBased = "Port-Based" LLIPSHBased = "PSH Flag-Based" EnableDca = "Direct Cache Access" InterruptThrottleRate = "Interrupt Moderation Rate" Adaptive = "Adaptive" Extreme = "Extreme" High = "High" Medium = "Medium" Low = "Low" IPChksumOffv4 = "IPv4 Checksum Offload" TCPChksumOffv4 = "TCP Checksum Offload (IPv4)" UDPChksumOffv4 = "UDP Checksum Offload (IPv4)" LsoV1IPv4 = "Offload TCP Segmentation" ChksumOffTxRx = "Rx & Tx Enabled" ChksumOffTx = "Tx Enabled" ChksumOffRx = "Rx Enabled" TransmitBuffers = "Transmit Buffers" ReceiveBuffers = "Receive Buffers" RSS = "Receive Side Scaling" NumRssQueues = "Receive Side Scaling Queues" 1queue = "1 Queue" 2queues = "2 Queues" 4queues = "4 Queues" FlowControl = "Flow Control" FlowControl_RxOnly = "Rx Enabled" FlowControl_TxOnly = "Tx Enabled" FlowControl_Full = "Rx & Tx Enabled" PriorityVLANTag = "Priority & VLAN" PriorityVlanDisabled = "Priority & VLAN Disabled" PriorityEnabled = "Priority Enabled" PriorityVlanEnabled = "Priority & VLAN Enabled" VlanEnabled = "VLAN Enabled" SpeedDuplex = "Speed & Duplex" AutoNegotiation = "Auto Negotiation" 1000Mb_Full_Duplex = "1.0 Gbps Full Duplex" 10Gb_Full_Duplex = "10 Gbps Full Duplex" On = "On" Off = "Off" Enabled = "Enabled" Disabled = "Disabled" Bytes4088 = "4088 Bytes" Bytes9014 = "9014 Bytes" LAA = "Locally Administered Address" JumboPacket = "Jumbo Packet" LogLinkState = "Log Link State Event" Enable_PME = "Enable PME" SmartSpeed = "Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\drivers\ixn51x64.sys" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0804] ; Chinese (Simplified) EnableLLI ="低延迟中断" LLIPorts ="低延迟中断端口" LLIPortBased ="基于端口的" LLIPSHBased ="基于 PSH 标记的" EnableDca ="直接缓存访问" InterruptThrottleRate ="中断节流率" Adaptive ="适应性" Extreme ="极值" High ="高" Medium ="中" Low ="低" IPChksumOffv4 ="IPv4 校验和分载传输" TCPChksumOffv4 ="TCP 校验和分载传输 (IPv4)" UDPChksumOffv4 ="UDP 校验和分载传输 (IPv4)" LsoV1IPv4 ="分载 TCP 分段" ChksumOffTxRx ="已启用 Rx 和 Tx" ChksumOffTx ="已启用 Tx" ChksumOffRx ="已启用 Rx" TransmitBuffers ="传输缓冲区" ReceiveBuffers ="接收缓冲区" RSS ="接收方调整" NumRssQueues ="接收方调整队列" 1queue ="1 个队列" 2queues ="2 个队列" 4queues ="4 个队列" FlowControl ="流程控制" FlowControl_RxOnly ="已启用 Rx" FlowControl_TxOnly ="已启用 Tx" FlowControl_Full ="已启用 Rx 和 Tx" PriorityVLANTag ="优先级和 VLAN" PriorityVlanDisabled ="已禁用优先级和 VLAN" PriorityEnabled ="已启用优先级" PriorityVlanEnabled ="已启用优先级和 VLAN" VlanEnabled ="已启用 VLAN" SpeedDuplex ="速度和双工" AutoNegotiation ="自动协商" 1000Mb_Full_Duplex ="1.0 Gbps 全双工" 10Gb_Full_Duplex ="10 Gbps 全双工" On ="开启" Off ="关闭" Enabled ="启用" Disabled ="禁用" Bytes4088 ="4088 字节" Bytes9014 ="9014 字节" LAA ="本地管理的地址" JumboPacket ="巨帧数据包" LogLinkState ="记录链接状态事件" Enable_PME ="启用 PME" SmartSpeed ="智能速度" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0404] ; Chinese (Traditional) EnableLLI ="┑筐耞" LLIPorts ="┑筐耞硈钡梆" LLIPortBased ="硈钡梆膀娄" LLIPSHBased ="PSH 篨腹膀娄" EnableDca ="钡е" InterruptThrottleRate ="耞竊瑈恢硉瞯" Adaptive ="秸俱┦" Extreme ="伐蔼" High ="蔼" Medium ="い" Low ="" IPChksumOffv4 ="IPv4 浪琩更" TCPChksumOffv4 ="TCP 浪琩更 (IPv4)" UDPChksumOffv4 ="UDP 浪琩更 (IPv4)" LsoV1IPv4 ="更 TCP 跋琿" ChksumOffTxRx ="Rx 籔 Tx 币ノ" ChksumOffTx ="Tx 币ノ" ChksumOffRx ="Rx 币ノ" TransmitBuffers ="肚块絯侥跋" ReceiveBuffers ="钡Μ絯侥跋" RSS ="钡Μ狠秸俱ゑ瞯" NumRssQueues ="钡Μ狠秸俱ゑ瞯︻" 1queue ="︻" 2queues ="ㄢ︻" 4queues ="︻" FlowControl ="瑈祘北" FlowControl_RxOnly ="Rx 币ノ" FlowControl_TxOnly ="Tx 币ノ" FlowControl_Full ="Rx 籔 Tx 币ノ" PriorityVLANTag ="纔抖籔 VLAN" PriorityVlanDisabled ="纔抖籔 VLAN 氨ノ" PriorityEnabled ="纔抖币ノ" PriorityVlanEnabled ="纔抖籔 VLAN 币ノ" VlanEnabled ="VLAN 币ノ" SpeedDuplex ="硉籔蛮" AutoNegotiation ="笆ユ疉" 1000Mb_Full_Duplex ="1.0 Gbps 蛮" 10Gb_Full_Duplex ="10 Gbps 蛮" On ="秨币" Off ="闽超" Enabled ="币ノ" Disabled ="氨ノ" Bytes4088 ="4088 じ舱" Bytes9014 ="9014 じ舱" LAA ="セ恨瞶" JumboPacket ="禬" LogLinkState ="祅魁硈挡篈ㄆン" Enable_PME ="币ノ PME" SmartSpeed ="笆ち传硉" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0407] ; German (Germany) EnableLLI ="Low Latency Interrupts (LLIs)" LLIPorts ="LLI-Anschl黶se" LLIPortBased ="Anschlussbasiert" LLIPSHBased ="PSH markierungsbasiert" EnableDca ="Direct Cache Access" InterruptThrottleRate ="Interrupt-Drosselungsrate" Adaptive ="Adaptiv" Extreme ="Extrem" High ="Hoch" Medium ="Mittel" Low ="Niedrig" IPChksumOffv4 ="IPv4-Pr黤summen abladen" TCPChksumOffv4 ="TCP-Pr黤summen abladen (IPv4)" UDPChksumOffv4 ="UDP-Pr黤summen abladen (IPv4)" LsoV1IPv4 ="TCP-Segmentierung abladen" ChksumOffTxRx ="Rx und Tx aktiviert" ChksumOffTx ="Tx aktiviert" ChksumOffRx ="Rx aktiviert" TransmitBuffers ="躡ertragungspuffer" ReceiveBuffers ="Empfangspuffer" RSS ="RSS (Empfangsseitige Skalierung)" NumRssQueues ="RSS-Warteschlangen (Empfangsseitige Skalierung)" 1queue ="1 Warteschlange" 2queues ="2 Warteschlangen" 4queues ="4 Warteschlangen" FlowControl ="Flusssteuerung" FlowControl_RxOnly ="Rx aktiviert" FlowControl_TxOnly ="Tx aktiviert" FlowControl_Full ="Rx und Tx aktiviert" PriorityVLANTag ="Priorit鋞 und VLAN" PriorityVlanDisabled ="Priorit鋞 und VLAN deaktiviert" PriorityEnabled ="Priorit鋞 aktiviert" PriorityVlanEnabled ="Priorit鋞 und VLAN aktiviert" VlanEnabled ="VLAN aktiviert" SpeedDuplex ="Geschwindigkeit & Duplex" AutoNegotiation ="Automatische Aushandlung" 1000Mb_Full_Duplex ="1,0 Gbit/s Vollduplex" 10Gb_Full_Duplex ="10 Gbit/s Vollduplex" On ="Ein" Off ="Aus" Enabled ="Aktiviert" Disabled ="Deaktiviert" Bytes4088 ="4088 Byte" Bytes9014 ="9014 Byte" LAA ="Lokal verwaltete Adresse" JumboPacket ="Jumbo Packet" LogLinkState ="Verbindungsereignis protokollieren" Enable_PME ="PME aktivieren" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0C0A] ; Spanish (Spain) EnableLLI ="Interrupciones de baja latencia" LLIPorts ="Puertos de interrupciones de baja latencia" LLIPortBased ="Basado en puerto" LLIPSHBased ="Basado en indicador PSH" EnableDca ="Acceso directo a cach" InterruptThrottleRate ="Velocidad de obstrucci髇 de la interrupci髇" Adaptive ="Adaptaci髇" Extreme ="Extremo" High ="Alto" Medium ="Medio" Low ="Bajo" IPChksumOffv4 ="Descarga de la suma de comprobaci髇 de IPv4" TCPChksumOffv4 ="Descarga de la suma de comprobaci髇 TCP (IPv4)" UDPChksumOffv4 ="Descarga de la suma de comprobaci髇 UDP (IPv4)" LsoV1IPv4 ="Descarga de segmentaci髇 TCP " ChksumOffTxRx ="Recepci髇 y transmisi髇 habilitadas" ChksumOffTx ="Transmisi髇 habilitada" ChksumOffRx ="Recepci髇 habilitada" TransmitBuffers ="B鷉eres de transmisi髇" ReceiveBuffers ="B鷉eres de recepci髇" RSS ="Receive Side Scaling" NumRssQueues ="Colas de Receive Side Scaling" 1queue ="1 cola" 2queues ="2 colas" 4queues ="4 colas" FlowControl ="Control de flujo" FlowControl_RxOnly ="Recepci髇 habilitada" FlowControl_TxOnly ="Transmisi髇 habilitada" FlowControl_Full ="Recepci髇 y transmisi髇 habilitadas" PriorityVLANTag ="Prioridad y VLAN" PriorityVlanDisabled ="Prioridad y VLAN inhabilitadas" PriorityEnabled ="Prioridad habilitada" PriorityVlanEnabled ="Prioridad y VLAN habilitadas" VlanEnabled ="VLAN habilitada" SpeedDuplex ="Velocidad y d鷓lex" AutoNegotiation ="Negociaci髇 autom醫ica" 1000Mb_Full_Duplex ="D鷓lex completo a 1,0 Gbps" 10Gb_Full_Duplex ="D鷓lex completo a 10 Gbps" On ="Activado" Off ="Desactivado" Enabled ="Habilitado" Disabled ="Inhabilitado" Bytes4088 ="4088 bytes" Bytes9014 ="9014 bytes" LAA ="Direcci髇 administrada localmente" JumboPacket ="Paquete jumbo" LogLinkState ="Registrar sucesos del estado del enlace" Enable_PME ="Activar PME" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.040C] ; French (France) EnableLLI ="Interruptions faible latence" LLIPorts ="Ports d'interruption faible latence" LLIPortBased ="Bas sur le port" LLIPSHBased ="Bas sur le drapeau PSH" EnableDca ="Acc鑣 direct au cache" InterruptThrottleRate ="Taux de gestion des interruptions" Adaptive ="Variable" Extreme ="Extr阭e" High ="Haut" Medium ="Moyen" Low ="Faible" IPChksumOffv4 ="D閘ester somme de contr鬺e IPv4" TCPChksumOffv4 ="D閘ester somme de contr鬺e TCP (IPv4)" UDPChksumOffv4 ="D閘ester somme de contr鬺e UDP (IPv4)" LsoV1IPv4 ="D閘ester la segmentation TCP" ChksumOffTxRx ="Rx et Tx activ閑s" ChksumOffTx ="Tx activ閑" ChksumOffRx ="Rx activ閑" TransmitBuffers ="Tampons d'閙ission" ReceiveBuffers ="Tampons de r閏eption" RSS ="Receive Side Scaling" NumRssQueues ="Files d抋ttente Receive Side Scaling" 1queue ="1 file d'attente" 2queues ="2 files d'attente" 4queues ="4 files d'attente" FlowControl ="Contr鬺e de flux" FlowControl_RxOnly ="Rx activ閑" FlowControl_TxOnly ="Tx activ閑" FlowControl_Full ="Rx et Tx activ閑s" PriorityVLANTag ="Priorit et VLAN" PriorityVlanDisabled ="Priorit et VLAN d閟activ閟" PriorityEnabled ="Priorit activ閑" PriorityVlanEnabled ="Priorit et VLAN activ閟" VlanEnabled ="VLAN activ" SpeedDuplex ="Vitesse et duplex" AutoNegotiation ="N間ociation automatique" 1000Mb_Full_Duplex ="1,0 Gbits/s full duplex" 10Gb_Full_Duplex ="10 Gbits/s full duplex" On ="Activ(e)" Off ="D閟activ(e)" Enabled ="Activ(e)" Disabled ="D閟activ(e)" Bytes4088 ="4088 octets" Bytes9014 ="9014 octets" LAA ="Adresse administr閑 localement" JumboPacket ="Paquet Jumbo" LogLinkState ="Consigner l'関閚ement de la liaison" Enable_PME ="Activer PME" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0410] ; Italian (Italy) EnableLLI ="Interrupt a bassa latenza" LLIPorts ="Porte di interrupt a bassa latenza" LLIPortBased ="Basato su porta" LLIPSHBased ="Basato su flag PSH" EnableDca ="Accesso diretto alla cache" InterruptThrottleRate ="Velocit di rallentamento dell'interrupt" Adaptive ="Adattivo" Extreme ="Estremo" High ="Alto" Medium ="Medio" Low ="Basso" IPChksumOffv4 ="Offload di checksum IPv4" TCPChksumOffv4 ="Offload di checksum TCP (IPv4)" UDPChksumOffv4 ="Offload di checksum UDP (IPv4)" LsoV1IPv4 ="Offload della segmentazione TCP" ChksumOffTxRx ="Rx e Tx abilitate" ChksumOffTx ="Tx abilitata" ChksumOffRx ="Rx abilitata" TransmitBuffers ="Trasmetti buffer" ReceiveBuffers ="Ricevi buffer" RSS ="Receive Side Scaling" NumRssQueues ="Code Receive-Side Scaling" 1queue ="1 coda" 2queues ="2 code" 4queues ="4 code" FlowControl ="Controllo del flusso" FlowControl_RxOnly ="Rx abilitata" FlowControl_TxOnly ="Tx abilitata" FlowControl_Full ="Rx e Tx abilitate" PriorityVLANTag ="Priorit e VLAN" PriorityVlanDisabled ="Priorit e VLAN disabilitate" PriorityEnabled ="Priorit abilitata" PriorityVlanEnabled ="Priorit e VLAN abilitate" VlanEnabled ="VLAN abilitata" SpeedDuplex ="Velocit e duplex" AutoNegotiation ="Negoziazione automatica" 1000Mb_Full_Duplex ="1.0 Gbps Full Duplex" 10Gb_Full_Duplex ="10 Gbps Full Duplex" On ="Attivato" Off ="Disattivato" Enabled ="Attivato" Disabled ="Disattivato" Bytes4088 ="4088 byte" Bytes9014 ="9014 byte" LAA ="Indirizzo amministrato localmente" JumboPacket ="Pacchetto Jumbo" LogLinkState ="Registra evento stato del collegamento" Enable_PME ="Abilita PME" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0411] ; Japanese (Japan) EnableLLI ="掅儗僀僥儞僔乕妱傝崬傒" LLIPorts ="掅儗僀僥儞僔乕妱傝崬傒億乕僩" LLIPortBased ="億乕僩 儀乕僗" LLIPSHBased ="PSH 僼儔僌 儀乕僗" EnableDca ="僟僀儗僋僩 僉儍僢僔儏 傾僋僙僗" InterruptThrottleRate ="妱傝崬傒壛尭棪" Adaptive ="傾僟僾僥傿僽" Extreme ="嵟戝" High ="崅" Medium ="拞" Low ="掅" IPChksumOffv4 ="IPv4 僠僃僢僋僒儉偺僆僼儘乕僪" TCPChksumOffv4 ="TCP 僠僃僢僋僒儉偺僆僼儘乕僪 (IPv4)" UDPChksumOffv4 ="UDP 僠僃僢僋僒儉偺僆僼儘乕僪 (IPv4)" LsoV1IPv4 ="TCP 僙僌儊儞僥乕僔儑儞偺僆僼儘乕僪" ChksumOffTxRx ="庴怣/憲怣 桳岠" ChksumOffTx ="憲怣 桳岠" ChksumOffRx ="庴怣 桳岠" TransmitBuffers ="憲怣僶僢僼傽" ReceiveBuffers ="庴怣僶僢僼傽" RSS ="庴怣懁僗働乕儕儞僌" NumRssQueues ="庴怣懁僗働乕儕儞僌 僉儏乕" 1queue ="1 僉儏乕" 2queues ="2 僉儏乕" 4queues ="4 僉儏乕" FlowControl ="僼儘乕惂屼" FlowControl_RxOnly ="庴怣 桳岠" FlowControl_TxOnly ="憲怣 桳岠" FlowControl_Full ="庴怣/憲怣 桳岠" PriorityVLANTag ="桪愭/VLAN" PriorityVlanDisabled ="桪愭/VLAN 柍岠" PriorityEnabled ="桪愭 桳岠" PriorityVlanEnabled ="桪愭/VLAN 桳岠" VlanEnabled ="VLAN 桳岠" SpeedDuplex ="懍搙偲僨儏僾儗僢僋僗" AutoNegotiation ="僆乕僩僱僑僔僄乕僔儑儞" 1000Mb_Full_Duplex ="1.0 Gbps 慡擇廳捠怣" 10Gb_Full_Duplex ="10 Gbps 慡擇廳捠怣" On ="僆儞" Off ="僆僼" Enabled ="僆儞" Disabled ="僆僼" Bytes4088 ="4088 僶僀僩" Bytes9014 ="9014 僶僀僩" LAA ="儘乕僇儖娗棟偝傟傞傾僪儗僗" JumboPacket ="僕儍儞儃 僷働僢僩" LogLinkState ="儕儞僋 僗僥乕僩 僀儀儞僩偺儘僌" Enable_PME ="PME 傪僆儞偵偡傞" SmartSpeed ="僗儅乕僩僗僺乕僪" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0412] ; Korean (Korea) EnableLLI ="撤篮 措扁 矫埃 牢磐反飘" LLIPorts ="撤篮 措扁 矫埃 牢磐反飘 器飘" LLIPortBased ="器飘 扁馆" LLIPSHBased ="PSH 敲贰弊 扁馆" EnableDca ="流立 某矫 咀技胶" InterruptThrottleRate ="牢磐反飘 炼例 加档" Adaptive ="利览" Extreme ="弥措" High ="臭澜" Medium ="吝埃" Low ="撤澜" IPChksumOffv4 ="IPv4 眉农级 坷橇肺靛" TCPChksumOffv4 ="TCP 眉农级 坷橇肺靛(IPv4)" UDPChksumOffv4 ="UDP 眉农级 坷橇肺靛(IPv4)" LsoV1IPv4 ="TCP 技弊刚飘拳 坷橇肺靛" ChksumOffTxRx ="Rx & Tx 劝己拳凳" ChksumOffTx ="Tx 劝己拳凳" ChksumOffRx ="Rx 劝己拳凳" TransmitBuffers ="傈价 滚欺" ReceiveBuffers ="荐脚 滚欺" RSS ="荐脚螟 硅啦" NumRssQueues ="荐脚螟 硅啦 措扁凯" 1queue ="1俺狼 措扁凯" 2queues ="2俺狼 措扁凯" 4queues ="4俺狼 措扁凯" FlowControl ="儒抚 力绢" FlowControl_RxOnly ="Rx 劝己拳凳" FlowControl_TxOnly ="Tx 劝己拳凳" FlowControl_Full ="Rx & Tx 劝己拳凳" PriorityVLANTag ="快急鉴困 棺 VLAN" PriorityVlanDisabled ="快急鉴困 棺 VLAN 厚劝己拳凳" PriorityEnabled ="快急鉴困 劝己拳凳" PriorityVlanEnabled ="快急鉴困 棺 VLAN 劝己拳凳" VlanEnabled ="VLAN 劝己拳凳" SpeedDuplex ="加档 棺 捞吝己" AutoNegotiation ="磊悼 蛆惑" 1000Mb_Full_Duplex ="1.0 Gbps 傈捞吝" 10Gb_Full_Duplex ="10 Gbps 傈捞吝" On ="柯" Off ="坷橇" Enabled ="劝己拳凳" Disabled ="厚劝己拳凳" Bytes4088 ="4088官捞飘" Bytes9014 ="9014官捞飘" LAA ="肺拿 包府 林家" JumboPacket ="痢焊 菩哦" LogLinkState ="傅农 惑怕 捞亥飘 扁废" Enable_PME ="PME 劝己拳" SmartSpeed ="胶付飘 胶乔靛" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0416] ; Portuguese (Brazil) EnableLLI ="Interrup珲es de baixa lat阯cia" LLIPorts ="Portas de interrup珲es de baixa lat阯cia" LLIPortBased ="Baseado em porta" LLIPSHBased ="Baseado no sinalizador PSH" EnableDca ="Acesso direto ao cache" InterruptThrottleRate ="Taxa de modera玢o de interrup珲es" Adaptive ="Adaptativa" Extreme ="Extremo" High ="Alto" Medium ="M閐io" Low ="Baixo" IPChksumOffv4 ="Offload Checksum IPv4" TCPChksumOffv4 ="Offload Checksum de TCP (IPv4)" UDPChksumOffv4 ="Offload Checksum UDP (IPv4)" LsoV1IPv4 ="Offload Segmenta玢o de TCP" ChksumOffTxRx ="Rx e Tx ativadas" ChksumOffTx ="Tx ativada" ChksumOffRx ="Rx ativada" TransmitBuffers ="Buffers de transmiss鉶" ReceiveBuffers ="Buffers de recep玢o" RSS ="Escala de recep玢o" NumRssQueues ="Filas de escalas de recep玢o" 1queue ="1 fila" 2queues ="2 filas" 4queues ="4 filas" FlowControl ="Controle de fluxo" FlowControl_RxOnly ="Rx ativada" FlowControl_TxOnly ="Tx ativada" FlowControl_Full ="Rx e Tx ativadas" PriorityVLANTag ="Prioridade e VLAN" PriorityVlanDisabled ="Prioridade e VLAN desabilitados" PriorityEnabled ="Prioridade ativada" PriorityVlanEnabled ="Prioridade e VLAN ativadas" VlanEnabled ="VLAN ativada" SpeedDuplex ="Velocidade e duplex" AutoNegotiation ="Negocia玢o autom醫ica" 1000Mb_Full_Duplex ="Full-duplex de 1.0 Gbps" 10Gb_Full_Duplex ="Full-duplex de 10 Gbps" On ="Ativado" Off ="Desativado" Enabled ="Habilitado" Disabled ="Desabilitado" Bytes4088 ="4088 Bytes" Bytes9014 ="9014 Bytes" LAA ="Endere鏾 administrado localmente (LAA)" JumboPacket ="Pacote grande" LogLinkState ="Evento de estado de link de registro" Enable_PME ="Habilitar PME" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0C04] ; Chinese (Traditional) EnableLLI ="┑筐耞" LLIPorts ="┑筐耞硈钡梆" LLIPortBased ="硈钡梆膀娄" LLIPSHBased ="PSH 篨腹膀娄" EnableDca ="钡е" InterruptThrottleRate ="耞竊瑈恢硉瞯" Adaptive ="秸俱┦" Extreme ="伐蔼" High ="蔼" Medium ="い" Low ="" IPChksumOffv4 ="IPv4 浪琩更" TCPChksumOffv4 ="TCP 浪琩更 (IPv4)" UDPChksumOffv4 ="UDP 浪琩更 (IPv4)" LsoV1IPv4 ="更 TCP 跋琿" ChksumOffTxRx ="Rx 籔 Tx 币ノ" ChksumOffTx ="Tx 币ノ" ChksumOffRx ="Rx 币ノ" TransmitBuffers ="肚块絯侥跋" ReceiveBuffers ="钡Μ絯侥跋" RSS ="钡Μ狠秸俱ゑ瞯" NumRssQueues ="钡Μ狠秸俱ゑ瞯︻" 1queue ="︻" 2queues ="ㄢ︻" 4queues ="︻" FlowControl ="瑈祘北" FlowControl_RxOnly ="Rx 币ノ" FlowControl_TxOnly ="Tx 币ノ" FlowControl_Full ="Rx 籔 Tx 币ノ" PriorityVLANTag ="纔抖籔 VLAN" PriorityVlanDisabled ="纔抖籔 VLAN 氨ノ" PriorityEnabled ="纔抖币ノ" PriorityVlanEnabled ="纔抖籔 VLAN 币ノ" VlanEnabled ="VLAN 币ノ" SpeedDuplex ="硉籔蛮" AutoNegotiation ="笆ユ疉" 1000Mb_Full_Duplex ="1.0 Gbps 蛮" 10Gb_Full_Duplex ="10 Gbps 蛮" On ="秨币" Off ="闽超" Enabled ="币ノ" Disabled ="氨ノ" Bytes4088 ="4088 じ舱" Bytes9014 ="9014 じ舱" LAA ="セ恨瞶" JumboPacket ="禬" LogLinkState ="祅魁硈挡篈ㄆン" Enable_PME ="币ノ PME" SmartSpeed ="笆ち传硉" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;-----------------------------------------------------------------------------